Health level sampling valve

当前位置:首页-Health level sampling valve
Aseptic sampling valve

Aseptic sampling valve

  • Stable quality, implement the whole process of quality control, nuanced, an overall inspection!
  • The price is reasonable, efficient internal cost control, reduce the costs, the savings to the customer!
  • Fast delivery: advanced production lines, sufficient stock, shorten the delivery time!

Aseptic sampling valve:
Aseptic sampling valve, yogurt sampling valve is mainly used for the inside of the tank equipment or piping material samples, and requirements in each sampling sterilization before and after treatment. No dead Angle, thorough sterilization, can be continuous and aseptic sampling at any time. Widely used in food, brewing, beverage, dairy products, toothpaste, cosmetics, biological pharmaceutical and other industries.
The working principle of
Not completely no dead Angle, sterilizing thoroughly.
It was not available steam or alcohol for disinfection in situ.
When steam requirement is dry, because the condensed water will damage the diaphragm. We suggest that a certain amount (usually 100 times or so) sampling operation or after sterilization treatment, timely replacement diaphragm.
Technical options
When specifications: 1/4 ', 3/8 ", 1/2 ", 3/4"
To remove the simple
When welding, clamp, screw thread (mm or inches)
When maximum working pressure: 6 bar
When working temperature: - 10 ℃ to 120 ℃
Have the largest sterilization temperature: 120 ~ 150 ° C:
When in contact with the material parts: 1.4404/1.4301 / AISI 304 AISI 316 l
When in contact surface products: Ra 0.8 microns or less
When the seals: EPDM/PTFE comply with FDA 17.2600